Back

BBR Verification Record

This template is a customer-focused process that focuses on consistently improving business operations management. It strives to ensure that all associated employees work toward the common goals of improving product or service quality, as well as improving the procedures that are in place for production.
Ergon - Lubbock 14842
06/19/2024

BBR Verification Record

This template is a customer-focused process that focuses on consistently improving business operations management. It strives to ensure that all associated employees work toward the common goals of improving product or service quality, as well as improving the procedures that are in place for production.

    Verified By

    Date

    Caliper S/N:

    Requirements

    Calibrate according to manufactures instructions in software

    • Pass
    • Flag
    • Fail

    Check for sticktion test with two 2g +/- 0.2 weights

    • Pass
    • Flag
    • Fail

    Check contact load and test load

    • Pass
    • Flag
    • Fail

    Gage block

    Verified against certificate results with calipers

    Gage block #

    Top (15.995 +/- .005mm)

    Red (14.997 +/- .005mm)

    White (12.995 +/- .005mm)

    Blue (9.996 +/- .005mm)

    Thick Beam

    Dimensions verified with calipers against certificate values

    Thick Beam #

    Thickness Certificate (6.41 +/- .1mm)

    Thickness Actual (6.41 +/- .1mm)

    Width Certificate (12.7 +/- .25mm)

    Width Actual (12.7 +/- .25mm)

    Length Certificate (127 +/- .5mm)

    Length Actual (127 +/- .5mm)

    Thin Beam

    Dimensions verified with calipers against certificate values

    Thin Beam #

    Thickness Certificate (1.3 +/- .3mm)

    Thickness Actual (1.3 +/- .3mm)

    Width Certificate (12.7 +/- .1mm)

    Width Actual (12.7 +/- .1mm)

    Length Certificate (127 +/- .5mm)

    Length Actual (127 +/- .5mm)

    Weights Verified

    100g +/- 0.2

    ID #

    Weight (g)

    ID #

    Weight (g)

    ID #

    Weight (g)

    ID #

    Weight (g)

    Weights Verified

    2g +/- 0.2

    ID #

    Weight (g)

    ID #

    Weight (g)

    Temperatures Verifed

    -12

    • Pass
    • Flag
    • Fail

    -18

    • Pass
    • Flag
    • Fail

    Maintenance as needed

    Action recommended

Source: Ergon - Lubbock 14842 (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.