    Every year replace the air inlet filters.

    • Pass
    • Flag
    • Fail

    Every year test the safety valves.

    • Pass
    • Flag
    • Fail

    Every year have temperature protection and motor overload tested.

    • Pass
    • Flag
    • Fail

    Inspect motor love joy and coupling.

    • Pass
    • Flag
    • Fail

    Every two years replace the check valves.

    • Pass
    • Flag
    • Fail

    Change Oil if necessary, range from 4,000 to 8,000 hours of use.

    • Pass
    • Flag
    • Fail

    Grease the bearings every 4,000 hours. Be sure to inspect the bearings at quarterly intervals between each greasing to ensure they remain sufficiently lubricated.

    • Pass
    • Flag
    • Fail
Source: MaintainX (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.