Back

Braun Dryer Annual PM

The Braun Dryer Annual Preventive Maintenance (PM) checklist is designed to ensure the reliable and efficient operation of Braun dryers by performing essential maintenance tasks on an annual basis
857 Boucherville QC - Cintas
08/23/2024

Braun Dryer Annual PM

The Braun Dryer Annual Preventive Maintenance (PM) checklist is designed to ensure the reliable and efficient operation of Braun dryers by performing essential maintenance tasks on an annual basis

    *** LOTO Confirmation Statement - DO NOT EDIT/REMOVE ***

    All hazardous energy has been isolated using LOTO procedures?

    All potential stored or residual energy has been relieved, disconnected, restrained, lowered, and/or otherwise rendered safe?

    Lock Out Tag Out

    LOTO Performed

    Food Safety Pre-Check

    Utilize the Cintas ENERGY CONTROL PROGRAM Checklist when applying LOTO.

    Burner Inspection and Safety Checks - Verify burner firing rate. Perform gas valve leakage test. Check gas train filter and replace if necessary. Inspect burner and diffuser plate integrity. Check diffuser plate and wings for chipping, cracking and debris build-up. Orifices/ports should be uniform and clean of debris. (Appendix 1)

    • 1.PNG
    • Pass
    • Flag
    • Fail

    Wash Internal Lint Vacuum Bag - Pony wash internal lint vacuum bag or replace if necessary. On heavy lint and oil operations, this task may be required to be completed more often. (Appendix 2)

    • 2.PNG
    • Pass
    • Flag
    • Fail

    Verify Moisture Inhibitor is Present - Replace moisture inhibitor in electrical panel annually. (Appendix 3)

    • ScreenShot2022-03-04at12.00.45PM.png
    • Pass
    • Flag
    • Fail

    Drive gearbox oil - Change the drive assembly gearbox oil. Use Mobil SHC 629 oil.

    • Pass
    • Flag
    • Fail

    Clean up - Clean up all tools, parts, and debris from the work area.

    • Pass
    • Flag
    • Fail

    Note Repairs Made or Needed. Generate Corrective Work Order for Needed Repairs.

    Food Safety Post-Check

Source: 857 Boucherville QC - Cintas (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.