Back

Bunn LCR-3 DBC® High Volume (with Scholle 1910LX): Preventive Maintenance

In order to maintain proper operation and long service life BUNN® recommends performing the preventive maintenance. To ensure you get a fresh, healthy brew when every time you use your Bunn Coffee Maker, cleaning of any removable parts is important. To get the best flavor from your mug of coffee, every part of the machine needs to be kept clean.
MaintainX
12/07/2022

Bunn LCR-3 DBC® High Volume (with Scholle 1910LX): Preventive Maintenance

In order to maintain proper operation and long service life BUNN® recommends performing the preventive maintenance. To ensure you get a fresh, healthy brew when every time you use your Bunn Coffee Maker, cleaning of any removable parts is important. To get the best flavor from your mug of coffee, every part of the machine needs to be kept clean.

    REPLACING THE PUMP TUBING

    The pumps and tubing used in the dispenser are designed to give maximum performance and long life. However, the tubes are a wear item and must be replaced periodically. How long the tubes last is dependent on usage and properties of the concentrate. Excessive wear will reduce the output of the pumps resulting in a weak mixed beverage. Bunn-O-Matic recommends replacing the Pump Tubing a minimum of once every 6 months or sooner if warranted.

    Note: Replacement Tube/Adapter Kits can be purchased from BUNN-O-MATIC.

    • Screenshot2021-09-01at6.42.45PM.png
    • Screenshot2021-09-01at6.43.11PM.png
    • Screenshot2021-09-01at6.43.30PM.png
    • Screenshot2021-09-01at6.43.55PM.png
    • Screenshot2021-09-01at6.44.19PM.png
    • Screenshot2021-09-01at6.44.37PM.png

    DRAINING THE HOT WATER TANK

    CAUTION: The dispenser must be disconnected from the power source throughout these steps.

    Note: The dispenser must be refilled using the Initial Fill & Heat steps before reconnecting the power source.

Source: MaintainX (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.