Recirculation Pump PM

Maintenance inspections can identify minor issues before they turn into costly repairs. Inspections ensure machines are working correctly and helps prevent equipment downtime.

    Machine Observation

    Inspect unit for leaks

    • Pass
    • Flag
    • Fail

    Remove expansion joint at inlet side and remove any plastic build up on impeller. Reinstall expansion joint and ensure bolts are tight and no leaks are present

    • Pass
    • Flag
    • Fail

    Remove valves down stream from pump and clean out valves that have become clogged.

    • Pass
    • Flag
    • Fail

    Remove all locks and restart pump.

    • Pass
    • Flag
    • Fail

    Ensure pump pressure is between 85-130 PSI

    Grease both zerk fittings and motor of recir. pump

    • Pass
    • Flag
    • Fail
Source: 539 Corpus Christi TX (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.