HomeIndustries Use Cases PricingResources Book a TourLog In to MaintainXIndustries Use Cases PricingResources Book a TourLog In to MaintainX Back Manufacturing / Industrial • MaintenanceCummins QSK60 G CM2358 K110 - Maintenance - DailyMaintainX10/24/2021Cummins QSK60 G CM2358 K110 - Maintenance - DailyAIR INTAKE MAINTENANCECheck air cleaner restriction indicator (where fitted)If the service indicator shows red, replace air cleaner elements and reset the air cleaner service indicator.Check air intake system for leaksVisually inspect the air intake system for signs of wear or damageCheck audibly when the generator set is running. To replace, contact your authorized distributor.COOLING MAINTENANCECheck coolant level of radiatorIf low, top up to coolant system specifications level, with Cummins recommended coolant mix.Check cooling fan blades and motorsVisually inspect the fan blades through the guarding for signs of wear or damage. To replace, contact your authorized distributor.Check coolant lines and radiator hoses for leaks, wear, and cracksVisually check for leaks, worn or damages hoses. To replace, contact your authorized distributor.Visually inspect the radiator through the guarding for blockage, build up of debris, signs of wear or damage. To clean or replace, contact your authorized distributor.CONTROL MAINTENANCECheck operation of Control PanelCheck display (the system will perform a control panel test on initial activation). To replace, contact your authorized distributor.EXHAUST MAINTENANCECheck all exhaust components, and hardware (fittings, clamps, fasteners, etc.)Visually inspect the exhaust system for signs of wear or damage.Check audibly when the generator set is running. To replace, contact your authorized distributor.Check exhaust condensation trapDrain condensation into a suitable container. Dispose of fluids in accordance with local legislation.GENERATOR SET MAINTENANCEGeneral GenSet inspectionOil pan heaterEngine oil level and reservoir (optional)Coolant levelCoolant heater(s)Battery heater (optional)Control heater (optional)Breather heater (optional)Daily Maintenance ProceduresMonitor fluid levels, oil pressure, and coolant temperature frequently.During operation, be alert for mechanical problems that could create unsafe or hazardous conditions.Source: Cummins (quickserve.cummins.com)
Back Manufacturing / Industrial • MaintenanceCummins QSK60 G CM2358 K110 - Maintenance - DailyMaintainX10/24/2021Cummins QSK60 G CM2358 K110 - Maintenance - DailyAIR INTAKE MAINTENANCECheck air cleaner restriction indicator (where fitted)If the service indicator shows red, replace air cleaner elements and reset the air cleaner service indicator.Check air intake system for leaksVisually inspect the air intake system for signs of wear or damageCheck audibly when the generator set is running. To replace, contact your authorized distributor.COOLING MAINTENANCECheck coolant level of radiatorIf low, top up to coolant system specifications level, with Cummins recommended coolant mix.Check cooling fan blades and motorsVisually inspect the fan blades through the guarding for signs of wear or damage. To replace, contact your authorized distributor.Check coolant lines and radiator hoses for leaks, wear, and cracksVisually check for leaks, worn or damages hoses. To replace, contact your authorized distributor.Visually inspect the radiator through the guarding for blockage, build up of debris, signs of wear or damage. To clean or replace, contact your authorized distributor.CONTROL MAINTENANCECheck operation of Control PanelCheck display (the system will perform a control panel test on initial activation). To replace, contact your authorized distributor.EXHAUST MAINTENANCECheck all exhaust components, and hardware (fittings, clamps, fasteners, etc.)Visually inspect the exhaust system for signs of wear or damage.Check audibly when the generator set is running. To replace, contact your authorized distributor.Check exhaust condensation trapDrain condensation into a suitable container. Dispose of fluids in accordance with local legislation.GENERATOR SET MAINTENANCEGeneral GenSet inspectionOil pan heaterEngine oil level and reservoir (optional)Coolant levelCoolant heater(s)Battery heater (optional)Control heater (optional)Breather heater (optional)Daily Maintenance ProceduresMonitor fluid levels, oil pressure, and coolant temperature frequently.During operation, be alert for mechanical problems that could create unsafe or hazardous conditions.Source: Cummins (quickserve.cummins.com)