Back

Service Operator's Inspection Checklist

Use this checklist to inspect fueling and service stations for safety and proper waste management. This checklist has been developed to help the operator control the risks associated with the storage and handling of fuel. Attendants and operators must be trained on the use of the specific equipment at their facility.
MaintainX
07/22/2022

Service Operator's Inspection Checklist

Use this checklist to inspect fueling and service stations for safety and proper waste management. This checklist has been developed to help the operator control the risks associated with the storage and handling of fuel. Attendants and operators must be trained on the use of the specific equipment at their facility.

    Location:

    Date:

    Inspection carried out by:

    Site perimeter

    Manifest box is in good condition, water tight and securely fastened with locking mechanism working properly.

    • Pass
    • Flag
    • Fail

    Check contents of manifest and site plan information:

    contacts information correct and up-to-date

    • Pass
    • Flag
    • Fail

    storage locations and quantities as shown are correct

    • Pass
    • Flag
    • Fail

    document is good condition and legible.

    • Pass
    • Flag
    • Fail

    Service station forecourt

    "Hardstand area above underground tanks, fill boxes and dispensing areas are in good condition. Note any damage. Take photos to assess if minor damage is increasing with time."

    • Pass
    • Flag
    • Fail

    Is the tanker fill exclusion zone clearly marked on the forecourt? Demarcations on pavement become worn and fade requiring a periodic refresh.

    • Pass
    • Flag
    • Fail

    Fill point caps and fill box seals are in good condition? No water should accumulate within them. Drain lever in fill box should be operating correctly.

    • Pass
    • Flag
    • Fail

    Correct fill and dip point markers are located for each tank? ULP-violet / white, PULP-yellow/white, Diesel-olive/black, E10-violet/orange

    • Pass
    • Flag
    • Fail

    Condition of Vent pipes?

    Are they secured and undamaged?

    • Pass
    • Flag
    • Fail

    Are they clear of vegetation within 3 m?

    • Pass
    • Flag
    • Fail

    Are vent caps present and functional?

    • Pass
    • Flag
    • Fail

    Ensure vent termination points are clear of any debris, exclude rain ingress and help diffuse and dissipate vapours.

    Are bollards that protect the dispensers, aboveground tanks and vent pipes in good condition and remain fit for purpose? Repair where impact has occurred and ensure they remain robust and effective.

    • Pass
    • Flag
    • Fail

    Are placards on aboveground tanks in good condition and clearly visible from normal approaches?

    • Pass
    • Flag
    • Fail

    Maintaining safety during tanker filling operations

    This section applies when a tanker vehicle is on site to deliver fuels and fill product tanks (e.g. petrol and LPG)

    Does the tanker vehicle position itself appropriately on site within the property boundaries?

    • Pass
    • Flag
    • Fail

    Are appropriate exclusion zones around connection points set up using barriers and safety signs? The tanker driver must comply with the Transport Operations (Road Use Management–Dangerous Goods) Regulation 2008 which requires an 8 m diameter exclusion zone for petrol and a 10 m exclusion zone for LPG from the tanker’s hose connection point.

    • Pass
    • Flag
    • Fail

    Are any dispensers within the exclusion area shut down for the duration of the transfer process?

    • Pass
    • Flag
    • Fail

    Dispensing area

    Are hosepipes, break away couplings and nozzles free of damage?

    • Pass
    • Flag
    • Fail

    Any visible signs of leaks? Ensure damage is promptly repaired. Latching devices must be removed from petrol dispensing nozzles

    • Pass
    • Flag
    • Fail

    ‘A Stop Engine. No Smoking’ sign must be clearly visible at each flammable liquid dispenser. Is this and any other safety sign clearly visible and legible?

    • Pass
    • Flag
    • Fail

    Fire extinguishers:

    A minimum of 2 x 9 kg ABE (powder) type extinguishers must be available in the dispensing area. Are they clearly visible in the direction of approach for vehicles?

    • Pass
    • Flag
    • Fail

    Note: 1 extinguisher is sufficient if diesel only is dispensed.

    Is it charged and ready for use? The needle in the pressure gauge of all fire extinguishers is in the green area.

    • Pass
    • Flag
    • Fail

    A yellow maintenance tag is attached and embossed with a date mark of last inspection which is within the previous 6 months?

    • Pass
    • Flag
    • Fail

    Any LPG dispenser and self serve and pay dispensers must have an easily accessible emergency stop button close to the dispensing area.

    • Pass
    • Flag
    • Fail

    Are there any visible spills in the dispensing area? Check on source of any leaks (e.g. hoses). Clean up residual liquids to avoid slips and trips or potential ignitions.

    • Pass
    • Flag
    • Fail

    Is there a spill kit easily accessible to the dispensing area?

    • Pass
    • Flag
    • Fail

    Where site specific spill containment equipment is made available such as drain covers, are they in good condition and accessible?

    • Pass
    • Flag
    • Fail

    "Is the dispensing area well illuminated during night time operations where applicable? Lighting should allow for all signs and pump information to be clearly visible. "

    • Pass
    • Flag
    • Fail

    LPG cylinder exchange facility

    Is a red Class 2.1 diamond and a ‘Flammable Gas – No Smoking, No Flame’ sign clearly visible on the cage?

    • Pass
    • Flag
    • Fail

    Are cage/s located away from trafficable areas? Exchange cylinder cages should be positioned so that impacts are minimised and away from potential ignition sources in well ventilated areas. Minimum separation distances from various items are detailed in the guide.

    • Pass
    • Flag
    • Fail

    Is the cage/s locked when not in use?

    • Pass
    • Flag
    • Fail

    Is the cage/s clear of any rubbish or accumulated combustible material? Avoid storages of fire timber or oil products next to cages.

    • Pass
    • Flag
    • Fail

    Is the emergency stop switch in the console area is clearly labelled?

    • Pass
    • Flag
    • Fail

    Are all the dispensing units clearly visible by direct vision or cameras?

    • Pass
    • Flag
    • Fail

    Is there an up-to-date emergency telephone/contact list adjacent to the control console?

    • Pass
    • Flag
    • Fail

    Is a copy of the site emergency plan easily accessible to the console operator?

    • Pass
    • Flag
    • Fail

    Do portable fuel containers for sale to the public comply with AS 2906-2001- Fuel containers –portable-plastic and metal? Containers should have an embossed marking indicating compliance.

    • Pass
    • Flag
    • Fail

    Are all hazardous chemicals and combustible liquids in packages stored and handled so they cannot contaminate food, food packaging and personal use products? Ensure such products are separated in retail areas.

    • Pass
    • Flag
    • Fail

    Is the first aid kit appropriately stocked and readily accessible?

    • Pass
    • Flag
    • Fail

    Documents and records

    Are the following available at the location unless otherwise specified?

    • Pass
    • Flag
    • Fail

    Hazardous chemical register and safety data sheets (SDS)?

    • Pass
    • Flag
    • Fail

    Site operating and maintenance procedures?

    • Pass
    • Flag
    • Fail

    Safe work procedure and permit system for conducting any repair or renovation work on the forecourt within the vicinity of the fuel dispensers and their associated hazardous areas?

    • Pass
    • Flag
    • Fail

    Acknowledgement letter that the site has notified as a manifest quantity workplace? May be retained at corporate office location.

    • Pass
    • Flag
    • Fail

    Acknowledgement letter from that the site has submitted the emergency plan? May be retained at corporate office location."

    • Pass
    • Flag
    • Fail

    Record of daily tank dips and stock reconciliation? Procedures must detail what to do if an issue is found (e.g. non-reconcilable volumes).

    • Pass
    • Flag
    • Fail

    Maintenance records for the site’s storage and handling systems? Examples include, tank and pipework inspections, cathodic protection system inspection reports, fire fighting system maintenance reports. While these may be kept at a central or corporate office location, they must be made available if requested by an inspector.

    • Pass
    • Flag
    • Fail

    Incident reporting and investigation system?

    • Pass
    • Flag
    • Fail

    Staff training logs and records? Console operators must know what constitutes and emergency what to do in an emergency such as dealing with gas leaks and fuel spills. They must also know actions to take to control ignition sources on the forecourt, and turning off pumps.

    • Pass
    • Flag
    • Fail

    Register of safety meetings and minutes?

    • Pass
    • Flag
    • Fail

    Using the table below, record each item found to be non compliant or unsatisfactory and ensure each item is assigned to a responsible person and actioned in an appropriate time frame.

    Item:

    Non compliance/issue:

    Corrective action:

    Responsible person:

    Date completed:

Source: MaintainX (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.