LUBRICATING
Blade lift cylinder support yoke (4 places)
REMARK: These are at the front and rear of the left and right cylinders.
CHECK ALTERNATOR DRIVE BELT TENSION, ADJUST
ADJUSTING
REMARK
CHECK LEVEL OF BATTERY ELECTROLYTE: Carry out this check before operating the machine.
WARNING
NOTICE: When adding distilled water in cold weather, add it before starting operations in the morning to prevent the electrolyte from freezing.
Inspect the battery electrolyte level at least once a month and follow the basic safety procedures given below.
WHEN CHECKING ELECTROLYTE LEVEL FROM SIDE OF BATTERY
If it is possible to check the electrolyte level from the side of the battery, check as follows.
REMARK: If distilled water is added to above the U.L. line, use a syringe to lower the level to the U.L. line. Neutralize the removed fluid with baking soda (sodium bicarbonate), then flush it away with a large amount of water or consult your Komatsu distributor or battery maker.
WHEN IT IS IMPOSSIBLE TO CHECK ELECTROLYTE LEVEL FROM SIDE OF BATTERY
If it is impossible to check the electrolyte level from the side of the battery, or there is no display of the UPPER LEVEL line on the side of the battery, check as follows.
Use the diagram below for reference, and check if the electrolyte reaches the bottom of the sleeve.
REMARK: If distilled water is added to above the bottom of the sleeve, use a syringe to lower the level to the bottom of the sleeve. Neutralize the removed fluid with baking soda (sodium bicarbonate), then flush it away with a large amount of water or consult your Komatsu distributor or battery maker.
WHEN IT IS POSSIBLE TO USE INDICATOR TO CHECK ELECTROLYTE LEVEL
If it is possible to use and indicator to check the electrolyte level, follow the instructions given.
CHECK BRAKE PERFORMANCE
WARNING: If the machine moves during the following operation, please contact your Komatsu distributor for repairs immediately.
NOTICE: Do not place the joystick in the 1st speed position. Otherwise, it will cause damage to the machine.
Before starting the engine, check that the area around the machine is safe, then do as follows.
CHECK OIL LEVEL IN DAMPER CASE, ADD OIL