Use this checklist for the service procedure and maintenance of your Prodigy Cuber. irregular water flow can cause premature contact resulting in a short freeze cycle, small bridge, long harvest and even a shut down on short freeze
MaintainX
10/08/2022

Scotsman Prodigy Cubers Spillway 291-849 Service Procedure

Use this checklist for the service procedure and maintenance of your Prodigy Cuber. irregular water flow can cause premature contact resulting in a short freeze cycle, small bridge, long harvest and even a shut down on short freeze

    The freeze cycle on a Prodigy cuber is controlled by an ice thickness sensor positioned in front of the ice making surface. It is triggered by water contact. Normally water only contacts the sensor when the ice is at the proper size. However, irregular water flow can cause premature contact resulting in a short freeze cycle, small bridge, long harvest and even a shut down on short freeze (code 8).

    The primary procedure for correcting poor water flow is to scrub the spillway surface.

    Spillway Surface

    • Screenshot2021-07-03at7.42.29AM.png

      Other short freeze causes include:

    Source: MaintainX (Community Member)

    Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.