Back

JLG | Liftpods FT140 - Daily Walk-Around Inspection

Walk around inspection checklists are proven to help prevent issues with your Liftpods. Proper inspections will always lead to better quality of the life of your equipment and reduce costs.
MaintainX
10/13/2022

JLG | Liftpods FT140 - Daily Walk-Around Inspection

Walk around inspection checklists are proven to help prevent issues with your Liftpods. Proper inspections will always lead to better quality of the life of your equipment and reduce costs.

    INSPECTION NOTE: On all components, make sure there are no loose or missing parts, everything is securely fastened, no visible damage, or excessive wear exists in addition to any other criteria mentioned.

      Rear Wheels

      Check for any debris stuck to or around wheels. Make sure axle bolts are fastened.

      • Pass
      • Flag
      • Fail

      Base Frame

      Check for cracks or corrosion, especially around the mast-stump base (see Figure 2-1.)

      • 1.PNG
      • Pass
      • Flag
      • Fail

      Check level indicator is clean, secure and responds to movement.

      • Pass
      • Flag
      • Fail

      Base - Platform Emergency Lowering Tool

      Check that the platform emergency lowering tool is in place on the base frame and in good working order.

      • Pass
      • Flag
      • Fail

      Mast Assembly(s) - (Check both mast assemblies on the FT140 model)

      No cracks or corrosion, especially around base of mast

      • Pass
      • Flag
      • Fail

      No excess wear, kinks, nicks or damage; slide pad running surfaces smooth and unobstructed; free of dirt or debris.

      • Pass
      • Flag
      • Fail

      Platform Latch Assembly

      With platform not mounted to mast, inspect the mast pin mounts and their connections for any signs of damage. If no damage is present to the mounts, with platform mounted to mast, check that latch assembly is engaged with bottom of mast pin mount when released, see Figure 2-4.

      • 2.PNG
      • Pass
      • Flag
      • Fail

      Adjustable Leveling Feet/Locking Castor Wheel

      Check for any debris stuck to or around mechanism

      • Pass
      • Flag
      • Fail

      Check for damage. FT70-Non-skid pads (on bottom of foot) must be in good working order. FT140 - Castor wheel swivels freely and wheel brake working properly.

      • Pass
      • Flag
      • Fail

      Swivel Castor Mechanism (FT70)

      Engage handle is not bent or broken.

      • Pass
      • Flag
      • Fail

      Check for any debris stuck to or around mechanism.

      • Pass
      • Flag
      • Fail

      Castor wheel swivels freely.

      • Pass
      • Flag
      • Fail

      Manual Descent Crank

      Ensure it is present and securely attached in platform

      • 3.PNG
      • Pass
      • Flag
      • Fail

      Platform Assembly and Gate

      Check mounting pins are not loose; platform railing is undamaged; self-closing entry gates are in proper working order; no cracks or corrosion visible.

      • Pass
      • Flag
      • Fail

      Tool Tray

      Tool tray is seated securely on the platform top and side rails and resting on the mast top carry handle.

      • Pass
      • Flag
      • Fail

      No cracks or bends in tray.

      • Pass
      • Flag
      • Fail

      Both of the straps are securely attached to the platform side rails (See Figure 2-6.).

      • 4.PNG
      • Pass
      • Flag
      • Fail

      Decals are in place and legible.

      • Pass
      • Flag
      • Fail

      Maximum Load: The maximum permissible load on the tool tray is 33 lb. (15kg) evenly distributed.

        Powerpack - Control and Drive Unit (FT70 - Control Unit optional)

        Ensure it is properly mounted and latched onto mast cap.

        • Pass
        • Flag
        • Fail

        Button, triggers and switches not obscured or damaged

        • Pass
        • Flag
        • Fail

        Decals secure and legible

        • Pass
        • Flag
        • Fail

        Emergency stop switch reset for operation

        • Pass
        • Flag
        • Fail

        Control markings legible

        • Pass
        • Flag
        • Fail

        Battery is installed and secure.

        • Pass
        • Flag
        • Fail
      Source: MaintainX (Community Member)

      Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.