Frymaster Universal Holding Cabinet (UHC) Models UHCP2, UHCP4, UHCPN4
The Frymaster Universal Holding Cabinet (UHC) is used to maintain the effectiveness of the heater plate and to reduce the risk of cross contamination. The complete instructions are available so you can follow the step-by-step procedure.
Frymaster Universal Holding Cabinet (UHC) Models UHCP2, UHCP4, UHCPN4
The Frymaster Universal Holding Cabinet (UHC) is used to maintain the effectiveness of the heater plate and to reduce the risk of cross contamination. The complete instructions are available so you can follow the step-by-step procedure.
Frymaster Universal Holding Cabinet (UHC) Models UHCP2, UHCP4, UHCPN4
Calibrate UHC Monthly PR 50 M1
Why
To ensure correct holding temperature and accuracy of computer controls
Time required
Time of day
Hazard icons
Tools and supplies
Procedure
1 Make sure UHC is clean and at proper operating temperature.
2 Read and compare temperature of top heater plate.
The button end of the probe is placed against the plate being measured.
UHC heater plates are hot.
3 Read and compare temperature of bottom heater plate.
The pyrometer is showing a temperature within five degrees of the cabinet display, an acceptable margin.
The UHC-P narrow doesn’t display setpoint, only plate temperatures.
Use the Palm Pilot to recalibrate the cabinet, following steps in the operator’s manual.
The UHC-P software in the Palm Pilot is used to recalibrate the cabinet.
4 Read and compare temperatures for all UHC slots.
The temperature of all the heater plates is tested against the reading of the pyrometer.
Tip: Read and compare temperatures one slot at a time during low-volume periods.
Source: Frymaster