    LUBRICATING

    • 1.PNG

    Blade lift cylinder support yoke (4 places)

    • 1.PNG

      REMARK: These are at the front and rear of the left and right cylinders.

      • 1.PNG
      • 2.PNG
      • 2.PNG
      • 2.PNG
      • 2.PNG

      CHECK ALTERNATOR DRIVE BELT TENSION, ADJUST

      • 3.PNG

      ADJUSTING

      • 4.PNG

      REMARK

      CHECK LEVEL OF BATTERY ELECTROLYTE: Carry out this check before operating the machine.

        WARNING

        NOTICE: When adding distilled water in cold weather, add it before starting operations in the morning to prevent the electrolyte from freezing.

          Inspect the battery electrolyte level at least once a month and follow the basic safety procedures given below.

          • 5.PNG

          WHEN CHECKING ELECTROLYTE LEVEL FROM SIDE OF BATTERY

          If it is possible to check the electrolyte level from the side of the battery, check as follows.

          REMARK: If distilled water is added to above the U.L. line, use a syringe to lower the level to the U.L. line. Neutralize the removed fluid with baking soda (sodium bicarbonate), then flush it away with a large amount of water or consult your Komatsu distributor or battery maker.

            WHEN IT IS IMPOSSIBLE TO CHECK ELECTROLYTE LEVEL FROM SIDE OF BATTERY

            If it is impossible to check the electrolyte level from the side of the battery, or there is no display of the UPPER LEVEL line on the side of the battery, check as follows.

            • 7.PNG

            Use the diagram below for reference, and check if the electrolyte reaches the bottom of the sleeve.

            • 8.PNG

            REMARK: If distilled water is added to above the bottom of the sleeve, use a syringe to lower the level to the bottom of the sleeve. Neutralize the removed fluid with baking soda (sodium bicarbonate), then flush it away with a large amount of water or consult your Komatsu distributor or battery maker.

              WHEN IT IS POSSIBLE TO USE INDICATOR TO CHECK ELECTROLYTE LEVEL

              If it is possible to use and indicator to check the electrolyte level, follow the instructions given.

                CHECK BRAKE PERFORMANCE

                WARNING: If the machine moves during the following operation, please contact your Komatsu distributor for repairs immediately.

                  NOTICE: Do not place the joystick in the 1st speed position. Otherwise, it will cause damage to the machine.

                    Before starting the engine, check that the area around the machine is safe, then do as follows.

                    CHECK OIL LEVEL IN DAMPER CASE, ADD OIL

                    • 10.PNG
                    • 11.PNG

                    REMARK

                    CHANGE OIL IN ENGINE OIL PAN, REPLACE ENGINE OIL FILTER CARTRIDGE AND BYPASS FILTER CARTRIDGE

                    (including engine by-pass filter cartridge)

                      WARNING: The oil is at high temperature after the engine has been operated, so never change the oil immediately after finishing operations. Wait for the oil to cool down before changing it.

                        CHANGE OIL IN ENGINE OIL PAN, REPLACE ENGINE OIL FILTER CARTRIDGE AND BYPASS FILTER CARTRIDGE

                        • 12.PNG

                        Even if the machine has not been operated for 500 hours, the oil and filter cartridge must be replaced when the machine has been operated for 12 months. In the same way, even if the machine has not been oper- ated for 12 months, the oil and filter cartridge must be replaced when the machine has been operated for 500 hours.

                          REPLACE FUEL FILTER CARTRIDGE

                          Prepare a filter wrench and a container to catch the fuel.

                            WARNING

                            NOTICE

                            • 13.PNG

                            If the filter cartridge is tightened too far, the packing will be damaged and this will lead to leakage of fuel. If the filter car- tridge is too loose, fuel will also leak from the packing, so always tighten to the correct amount.

                              • 14.PNG
                              • 15.PNG
                              • 15.PNG

                              REMARK: When only the filter cartridge is replaced, it is suffficient that air bleeding is carried out for the filter head alone. But when the fuel piping is removed, air bleeding should also be carried out for the injection pump air-bleeding valve.

                                REPLACE POWER TRAIN OIL FILTER ELEMENT, STEERING LUBRICATING OIL FILTER ELEMENT

                                WARNING

                                • 16.PNG

                                CHECK OIL LEVEL IN FINAL DRIVE CASE, ADD OIL

                                WARNING: There is danger that the oil may spurt out under internal pressure, so to the side, and gradually turn the plug to release the internal pressure before removing the plug completely.

                                  • 17.PNG
                                  • 17.PNG
                                  • 17.PNG

                                  REPLACE HYDRAURIC TANK BREATHER ELEMENT

                                  WARNING:

                                  • 18.PNG
                                  • 18.PNG
                                  • 19.PNG
                                Source: MaintainX (Community Member)

                                Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.