Bunn LCA-1 LP Low Profile (with Scholle 1910LX): Preventive Maintenance
Use this checklist for the daily cleaning of your coffee machine. It provides many benefits including general hygiene and improving the taste of your coffee.
Bunn LCA-1 LP Low Profile (with Scholle 1910LX): Preventive Maintenance
Use this checklist for the daily cleaning of your coffee machine. It provides many benefits including general hygiene and improving the taste of your coffee.
REPLACING THE PUMP TUBING
The pumps and tubing used in the dispenser are designed to give maximum performance and long life. However, the tubes are a wear item and must be replaced periodically. How long the tubes last is dependent on usage and properties of the concentrate. Excessive wear will reduce the output of the pumps resulting in a weak mixed beverage. Bunn-O-Matic recommends replacing the Pump Tubing a minimum of once every 6 months or sooner if warranted. Refer to the Tube Replacement Instruction inside the Cabinet door.
REPLACING THE PUMP TUBING
Note: Rinse tubing with warm water (steps 1 - 4 of the Weekly Sanitizing Instructions) prior to removing to avoid spills.
REPLACING THE WATER FILTER:
CALIBRATING THE DISPENSER
NOTE: The LCA-1 is calibrated at the factory and does not normally need to be re-calibrated. Open the dispenser door to access the digital Programming Switches with LED display. To enter the Calibration Mode, Set the RUN/ NIGHT/PROGRAM Switch to the PROGRAM position and then hold both Up and Down Arrow switches until “1 r u n” appears of the display, (approx 15 sec).