Consequently, the food and drink industry and healthcare sectors use ATP testing extensively for hygiene and safety purposes. Testing for the presence of ATP helps businesses dealing with food preparation to verify the effectiveness of their cleaning routines, as well as their quality assurance and control purposes
Trillium Flow Technologies
02/14/2025

HAAS Non-Compact ATP Adjustment

Consequently, the food and drink industry and healthcare sectors use ATP testing extensively for hygiene and safety purposes. Testing for the presence of ATP helps businesses dealing with food preparation to verify the effectiveness of their cleaning routines, as well as their quality assurance and control purposes

    Step 1

    Operate this code in [MDI] mode for 3 minutes:

    If the ATP arm [2] does not align with home block [1], use the 3/8-24" setscrew [3] to move it toward or away from the home block.

    • AdjustmentPictograph1.webp
    • Pass
    • Flag
    • Fail

    Section #2

    • AdjustmentPictograph2.webp

    If the tool does not align with the center of the stylus, turn the top 3/8-24" x 2" setscrew [3] to move the stylus up or down.

    • AdjustmentPictograph2.webp
    • Pass
    • Flag
    • Fail
Source: Trillium Flow Technologies (Community Member)

Please note that any procedure, checklist, or other document available in the MaintainX Procedure Hub is provided for general education and information only and does not constitute legal, medical, or financial advice. MaintainX makes the materials available AS IS and AS PROVIDED, without warranties of any kind. By downloading or using any such materials, you assume the risk that they may not be appropriate for your specific situation and agree that you are solely responsible for any such use, including compliance with applicable law and with meeting any conditions of product warranties.