Manitowoc Blend-In-Cup® (BIC) Manual Fill Beverage System Weekly Maintenance
The Manitowoc Blend-In-Cup® (BIC) Manual Fill Beverage System Weekly Maintenance helps you in several ways: avoid expensive repairs, reduce downtime, keep beverage quality high, and extend the life of your equipment meaning you get to enjoy your investment for more years to come. This weekly maintenance form will help your equipment working in optimal conditions, leading to fewer failures, better productivity, higher profitability, and improved safety.
Manitowoc Blend-In-Cup® (BIC) Manual Fill Beverage System Weekly Maintenance
The Manitowoc Blend-In-Cup® (BIC) Manual Fill Beverage System Weekly Maintenance helps you in several ways: avoid expensive repairs, reduce downtime, keep beverage quality high, and extend the life of your equipment meaning you get to enjoy your investment for more years to come. This weekly maintenance form will help your equipment working in optimal conditions, leading to fewer failures, better productivity, higher profitability, and improved safety.
NOTE: The following procedures are the basic weekly cleaning instructions, on-screen instructions can vary depending on the recipe that was created with the MenuConnect program or options chosen in the Managers Menu.
*These items are optional and may not be displayed on all easyToUCH screens during ZONE 2 Cleaning.
Time to complete - 90 Minutes
NOTE: An additional 1 hour 45 minutes will be needed if the Sanitizing Ice bin option is enabled in the Managers Menu.
NOTE: Failure to complete the weekly cleaning sequence entirely will not reset the weekly cleaning timer and will require the process to be repeated.
GATHER THE FOLLOWING SUPPLIES
Follow the on-screen instructions and gather the following supplies:
NOTE: If other cleaners are used, it is possible they will not clean or sanitize your machine to NSF standards.
PRODUCT LINE CLEANING & SANITIZING
At Back Room Sink
Put on gloves & safety glasses
Prepare Cleaning Solutions
Follow the on screen instructions and fill each labeled bucket to the fill line with the appropriate solution and bring to machine.
Whip Cream Door *, Gasket Seals, & Drip Tray
Washing Instructions
Spray and wipe refrigerator surfaces with new sanitized clean cloth, including each
Connect Cleaning Tubes
Rinse Lines
Sanitize Lines
Whip Cream Door *, Gasket Seals, & Drip Tray
Purging Lines
NOTE: Air is pushed through each line (slot) blowing out any remaining liquid, displaying the progress on the screen, 30 seconds per slot. When purging has completed the Reinstall Inventory Screen will appear automatically
Reinstall Inventory
NOTE: This will automatically prime each line with product. The screen will read Priming Slot X. Each slot will change from Purged to Primed. When priming has completed the Prime Completion Screen will appear automatically.
Auto Prime Complete
Important : Do Not pour down the drain on the BIC unit!
Empty Ice Bin
Warning: Sharp Objects/Surfaces - Beware of the shaver blade located in the bottom of the ice bin.
Dispense Remaining Ice
NOTE: Ice will not dispense if ice bin lid is not in place.
Ice Bin Wash
Warning: When in contact with cleaning and sanitizing solution chemicals gloves and safety glasses are recommended.
NOTE: Do not put in dishwasher or power soaker.
BLENDERS / DISPENSE AREA CLEANING & SANITIZING
Grate Removal / Blender Station Wash
Warning: The blender station contains sharp moving parts. Wear gloves to protect hands.
Follow the on screen instructions:
Put on gloves and safety glasses.*
Blender Door Removal
Blender Station Wash
Clean Blender Shaft Bushing
Wash Blender Grate(s) / Door(s)
Warning : When in contact with cleaning and sanitizing solution chemicals gloves and safety glasses are recommended.
Reinstall Blender Door(s)
Reinstall Blender Grate(s)
Blender Wash
Blender Sanitizing
Blender Station Sanitizing
Warning: The blender station contains sharp moving parts. Wear gloves to protect hands.
Whipped Cream Door Cleaning *
Dispense Area Cleaning
,Caution: Do Not Insert a brush or sharp object into the red dispense nozzles.
Dispensing Area Sanitizing
NOTE: The touch screen will return to the Main Menu screen if Drain Cleaning is not active.
DRAIN CLEANING - BIO-SHIELD® (OPTIONAL)
*Only for units with this feature. These steps will only display during the ZONE 2 Cleaning on units with this feature turned on in the loaded recipe file. If this feature is not active, the interface will automatically proceed to “Weekly Cleaning Complet
Prepare Unit for Drain Cleaning
Prepare Drain Cleaning Solution
Mix Drain Cleaning Solution
Important: When in contact with drain cleaning chemicals gloves and safety glasses are recommended.
Drain Cleaning
Post Drain Cleaning
Reinstall Grate(s) / Door(s)
Important: Drain cleaner is most effective when left for four (4) hours, but the machine can be used as needed.
Source: Manitowoc (www.partstown.com)